PHOE Electricals Trading LLC - Leading electrical and automation supplier in Dubai UAEPHOE Electricals Trading LLC
Back to Blog
Circuit Breakers

Schneider Electric ACB Supplier in UAE – Complete MasterPact Air Circuit Breaker Buying Guide

February 1, 2025
10 min read
By PHOE Electricals Team
Schneider Electric ACB Supplier in UAE – Complete MasterPact Air Circuit Breaker Buying Guide

What Is an Air Circuit Breaker (ACB)?

An Air Circuit Breaker is an electrical protection device designed to protect low-voltage electrical distribution systems against faults such as overloads and short circuits.

ACBs are commonly installed in main distribution boards, power control centres, industrial switchboards and large commercial electrical installations.

Unlike smaller circuit protection devices used in final distribution circuits, ACBs are generally selected for higher-current applications and main power distribution systems.

Typical applications include:

  • Main Low Voltage (LV) distribution boards.
  • Industrial power distribution panels.
  • Commercial buildings and infrastructure.
  • Manufacturing facilities.
  • Generator incomer and outgoing feeders.
  • Transformer secondary protection.
  • Electrical power control centres.
  • Large commercial and industrial installations.

Schneider Electric MasterPact Air Circuit Breakers

Schneider Electric's MasterPact family includes advanced air circuit breakers designed for low-voltage power distribution and protection applications.

The MasterPact range includes different breaker generations and configurations, with selection depending on current rating, breaking capacity, installation requirements and protection functions.

1. Schneider Electric MasterPact MTZ

The MasterPact MTZ range is designed for modern electrical distribution systems and offers advanced protection, monitoring and communication capabilities depending on the selected model and trip unit.

Key selection considerations include:

  • Available frame and current ratings.
  • Breaking capacity requirements.
  • Electronic trip-unit selection.
  • Protection and measurement functions.
  • Communication and monitoring options.
  • Fixed or draw-out installation.
  • Auxiliary contacts and accessories.

MasterPact MTZ circuit breakers are used in industrial, commercial and infrastructure applications where advanced circuit protection and electrical system monitoring are required.

2. Schneider Electric MasterPact NW

MasterPact NW is another established Schneider Electric air circuit breaker family used in low-voltage power distribution systems.

It is available in different current ratings and configurations to meet various electrical installation requirements.

Important selection factors include:

  • Rated current.
  • Number of poles.
  • Breaking capacity.
  • Trip-unit type.
  • Fixed or draw-out construction.
  • Electrical and mechanical accessories.
  • Compatibility with the existing switchboard.

When replacing an existing MasterPact NW breaker, it is important to verify the complete reference number and configuration rather than selecting a replacement based only on the ampere rating.

Common Schneider Electric ACB Current Ratings

MasterPact air circuit breakers are available in different current-rating categories depending on the product generation and frame.

Current RatingTypical Application
630ASmall and medium LV distribution systems
800ACommercial and industrial distribution
1000AIndustrial power distribution
1250AMain distribution applications
1600AIndustrial switchboards
2000ALarge power distribution systems
2500AMain LV distribution boards
3200AHigh-current industrial applications
4000ALarge industrial power systems
5000AHigh-capacity distribution
6300ALarge-scale power distribution

These are common current-rating requirements, not a guarantee that every rating is available in every MasterPact generation or configuration.

The correct breaker must be selected using the manufacturer's technical catalogue and the electrical design requirements.

How to Select the Correct Schneider Electric ACB

Before purchasing a Schneider Electric MasterPact air circuit breaker, check the following technical details.

1. Rated Current (In)

Rated current represents the current-carrying rating of the selected breaker or its associated rating configuration.

Common project requirements include 1600A, 2000A, 2500A, 3200A and 4000A.

2. Breaking Capacity

Breaking capacity determines the maximum prospective short-circuit current the circuit breaker can safely interrupt under its specified operating conditions.

The required breaking capacity must be established from the electrical system's fault-level calculation.

3. Number of Poles

Depending on the installation, ACBs may be required in 3-pole or 4-pole configurations.

The selection depends on the distribution system and project design.

4. Fixed or Draw-Out Configuration

MasterPact ACBs may be selected in fixed or draw-out configurations, depending on the product family.

A draw-out breaker allows the circuit breaker to be withdrawn from its chassis for inspection or maintenance without removing the complete switchboard assembly.

5. Trip Unit and Protection Functions

Electronic trip units provide different protection functions depending on the selected model.

Typical protection considerations include:

  • Long-time protection.
  • Short-time protection.
  • Instantaneous protection.
  • Ground-fault protection, where supported.
  • Measurement and monitoring functions.

6. Accessories and Control Requirements

The required accessories should be checked before ordering.

These may include auxiliary contacts, closing coils, opening releases, undervoltage releases, motor mechanisms, communication modules and mechanical interlocks, depending on the breaker configuration.

MasterPact MTZ vs MasterPact NW – What Is the Difference?

Both product families serve low-voltage power distribution applications, but their features, generations and available configurations differ.

FeatureMasterPact MTZMasterPact NW
Product familyModern generationEstablished generation
ProtectionAdvanced electronic trip optionsElectronic trip options
MonitoringAdvanced digital capabilities depending on configurationDepends on trip unit and configuration
ApplicationsModern LV distributionLV distribution
SelectionBased on exact model and requirementsBased on exact model and requirements

For replacement projects, always verify the existing breaker reference, chassis compatibility, accessories and manufacturer's approved replacement information.

Schneider Electric ACB Supplier in Dubai, UAE

Finding the correct air circuit breaker is important for project delivery, electrical maintenance and switchgear replacement.

PHOE Electricals Trading LLC is based in Dubai, United Arab Emirates, and supports customer enquiries for Schneider Electric electrical distribution products and low-voltage switchgear.

Our Schneider Electric product enquiries include:

  • MasterPact MTZ Air Circuit Breakers.
  • MasterPact NW Air Circuit Breakers.
  • Schneider Electric MCCBs.
  • Schneider Electric MCBs.
  • RCCBs and RCBOs.
  • TeSys contactors and overload relays.
  • Electrical distribution and protection products.

We assist electrical contractors, MEP companies, panel builders, industrial facilities, maintenance teams, procurement departments and electrical wholesalers with product sourcing and quotation enquiries.

Schneider Electric ACB Supply Enquiries Across UAE and International Markets

Based in Dubai, PHOE Electricals supports electrical product enquiries from customers across the UAE, including Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, Umm Al Quwain and Al Ain.

We also support international product sourcing and supply enquiries from Saudi Arabia, Oman, Kuwait, Jordan, the United Kingdom and African markets, including Nigeria, Kenya, Ghana, Ethiopia, Rwanda, Uganda, Tanzania, Malawi, Sudan, Cameroon and Mozambique.

For international enquiries, delivery arrangements, documentation and product availability are confirmed according to the specific order requirements.

How to Request a Schneider Electric ACB Quotation

To help identify the correct MasterPact air circuit breaker, customers should provide the following information:

  1. Required current rating, such as 1600A, 2500A or 3200A.
  2. MasterPact model or complete part number, if available.
  3. Number of poles: 3P or 4P.
  4. Breaking capacity requirement.
  5. Fixed or draw-out configuration.
  6. Required trip unit and protection functions.
  7. Accessories and control voltage requirements.
  8. Required quantity and delivery location.

If you have an existing breaker, sharing its nameplate photograph or complete reference number can help with product identification.

Contact PHOE Electricals Trading LLC for Schneider Electric ACB Enquiries

If you are looking for a Schneider Electric ACB supplier in Dubai, MasterPact air circuit breakers in UAE, or low-voltage switchgear for an industrial or commercial project, contact PHOE Electricals Trading LLC.

Our team can assist with product enquiries, part-number identification, availability checks and quotations.

PHOE Electricals Trading LLC

Electrical Products Supplier – Dubai, United Arab Emirates

Website: www.phoeelectric.com

Email: info@phoeelectric.com

Frequently Asked Questions

Who supplies Schneider Electric ACBs in Dubai?

PHOE Electricals Trading LLC is a Dubai-based electrical products supplier that accepts enquiries for Schneider Electric MasterPact air circuit breakers and other electrical distribution products. Contact the team for product availability and quotations.

Where can I buy a Schneider Electric MasterPact 2500A ACB in UAE?

You can contact PHOE Electricals Trading LLC in Dubai with your required MasterPact model, configuration and technical specifications to request availability and pricing.

What is the difference between MasterPact MTZ and NW?

MasterPact MTZ is a newer product family with advanced digital monitoring and protection capabilities, while MasterPact NW is an established range. The correct choice depends on the installation, technical requirements and product compatibility.

What ACB current ratings are available?

MasterPact product families cover different current ratings depending on the model and configuration. Common requirements include 630A, 800A, 1250A, 1600A, 2500A, 3200A, 4000A and higher ratings.

What is the difference between fixed and draw-out ACBs?

A fixed ACB is installed directly into the switchboard, whereas a draw-out ACB is mounted on a compatible chassis and can be withdrawn for inspection or maintenance.

Can I request a Schneider Electric ACB quotation using a part number?

Yes. Providing the complete manufacturer reference number is one of the best ways to identify the required breaker configuration. A nameplate photograph is also useful when the part number is unavailable.

Does PHOE Electricals supply other Schneider Electric products?

PHOE Electricals also handles enquiries for Schneider Electric MCCBs, MCBs, RCCBs, RCBOs, contactors, overload relays, switches, sockets and industrial control products.

Need Help with Circuit Breakers?

Our expert team at PHOE Electricals is here to help you with product selection, technical specifications, and installation guidance.

Get Expert Assistance